EL-905U-L-P3-US

EL-905U-L-P3-US

I/O Radio Kit: (1)905U-L-T + (1)905U-L-R + (1)SER-RJ45, paired radios. MUST add antennas.

 

905U-L I/O - Data Sheet

The ELPRO 105U-L and 905U-L products are a small I/O count transmitter and receiver pair delivered pre-configured for ease of installation. Just connect the antennas and apply power for them to be operational.  The L series products may be reconfigured into a wider ELPRO I/O or gateway network as application needs grow. DIN rail mounted and DC (9-30V) powered, the units can also power a loop powered device to 24VDC, 30mA.

Features:

  • Flexible usage: pre-configured matched transmitter/ receiver pair; individual use for transmission/ receiving I/O from other devices.
  • Peer-to-peer communications with exception reporting, self-checking of messages via update time and secure data encryption.
  • Multi-hop repeatability of signals when used with multi-I/O and gateway units.
  • Up to 3000 wireless units per network.
  • Class I Div 2 hazardous area approval (USA/Canada).

Applications: Flow meter monitoring, Storage tank monitoring, Pipeline cathodic protection, Pump stop-start, Lighting bank control, Power reticulation relay fault notifications, Emergency shower notification, Weather station reporting, Bearing condition monitoring

Transmitter Unit Specific Features: Input-only I/O: 2 DI/PI (digital inputs can be pulse inputs), 1 AI, 1 TI (thermocouple mV input). Additional internal inputs: set point (analog), power supply voltage, 24VDC, 30mA analog loop supply.

Receiver Unit Specific Features: Output-only I/O: 3 digital relay/ 1 analog outputs. Communications failure indication and configurable output (retained or reset/fail-safe on communications failure). LED indication of radio signal strength.

I/O Radio (Receiver Only): 900MHz, 1W, I/O = (3)DO + (1)AO

 

  • Multi-hop repeatability of signals when used with multi-I/O and gateway units.
  • Up to 3000 wireless units per network.
  • Class I Div 2 hazardous area approval (USA/Canada).

Applications: Flow meter monitoring, Storage tank monitoring, Pipeline cathodic protection, Pump stop-start, Lighting bank control, Power reticulation relay fault notifications, Emergency shower notification, Weather station reporting, Bearing condition monitoring

Transmitter Unit Specific Features: Input-only I/O: 2 DI/PI (digital inputs can be pulse inputs), 1 AI, 1 TI (thermocouple mV input). Additional internal inputs: set point (analog), power supply voltage, 24VDC, 30mA analog loop supply.

Receiver Unit Specific Features: Output-only I/O: 3 digital relay/ 1 analog outputs. Communications failure indication and configurable output (retained or reset/fail-safe on communications failure). LED indication of radio signal strength.